Operation and configuration – Ivoclar Vivadent P710 User Manual

Page 39

Advertising
background image

39

5.2.7 Starting and stopping programs / the operating indicator
Once the program is started by pressing START, the firing curve display appears.

The following information is displayed:

– Information bar
In the information bar in the upper margin of the display, program name and the current furnace temperature are

indicated.

– Main area
The vacuum is shown on the left side of the main screen. The progress of the program is shown in the form of a firing

curve. The estimated remaining time is also displayed in 10-second intervals. If no vacuum is activated, the vacuum
indicator and all the corresponding parameters are blank.

The process status is shown in colour in the firing curve:
– Orange: Program is closing the furnace head or is in predrying mode
– Red: Program is heating up or is in holding time mode
– Blue: Program is in long-term cooling or is opening the furnace head

Active firing program options are shown in the grid next to the [Options] button.

If a two-stage program is selected, the firing curve is shown in two stages.

5. Operation and Configuration

Advertising
This manual is related to the following products: