Operating instructions, Gas and ac operation, Warning ! regulating the temperature – Dometic RM2553 User Manual

Page 10: Turning off the refrigerator

Advertising
background image

10

OPERATING INSTRUCTIONS

GAS AND AC OPERATION

LP gas operation

Before starting the refrigerator, check that all the manual

gas valves are in the ON position. Do not forget the manual

shutoff valve on the rear of the refrigerator.

To start the refrigerator, turn knob A to the “GAS”

position.
Turn the thermostat knob B to position 4.
Press and hold button C and press button D for the

piezo igniter several times to light the burner. This

can be observed on the flame indicator E. When

the flame is on, the red indicator is in the green

field (ON).
After the gas is lit, keep the button C pressed for

10 seconds. Release the button and check that the

RED indicator is in the GREEN field, (ON).
To shut off the refrigerator turn the knob A to

“OFF”.

Note! After changing an LP tank, or after a long shut off pe-

riod, the gas line is likely to be filled with air. You may have

to repeat the lighting procedure several times to purge the air

out of the gas lines.

230-240 v AC OPERATION

Before operating the refrigerator, check that the voltage

stated on the data plate is the same as the main voltage in use.

Check to be sure that the power cord is properly

connected to the power supply.
Turn the knob A to the position marked “AC” for

230-240 volt AC operation.
Turn the thermostat knob B to position 4.

1.

2.
3.

4.

5.

1.

2.

3.

Whilst mobile:
- Do not operate the refrigerator on LP gas.

- Turn off the gas bottle.

WARNING

!

REGULATING ThE TEMPERATURE

The refrigerator is equipped with a thermostat that can be

adjusted by turning the knob B to different setting to maintain

the desired cabinet temperature.
Gas operation

At “OFF, the thermostat closes its main valve and the

burner runs continuously at the bypass rate, just enough to

keep the burner lit.

At “MAX”, the thermostat allows the burner to remain on

high flame continuously.

AC operation (230-240 V AC)

At “OFF, the contacts in the thermostat are open and the

heating elements are off.

At “MAX”, the heating element is “ON” continuously.

Lowest cabinet and freezer temperatures are obtained at

this setting.

The thermostat can be adjusted between “MAX” and “OFF”

to obtain the desired cabinet temperature. The closer the knob

is to “MAX” - the colder the cabinet temperature. The closer

the knob is to “OFF” - the warmer the cabinet temperature.
When the thermostat reaches the set temperature, it will cut

the burner back to bypass or, in electric operation (230-

240 V AC), shut off the heating element. The setting of the

thermostat is not critical, but we recommend it be adjusted

to maintain a dry frost on the cooling fins. Adjust the ther-

mostat knob closer to “MAX” when the outside temperature

becomes warm.

TURNING OFF ThE REFRIGERATOR

To shut off the refrigerator turn the knob A to
“OFF”.

If the refrigerator will not be in operation for a

period of weeks, it should be emptied, defrosted,

cleaned and the door left ajar. The ice tray should

also be dried and kept outside the cabinet.