Legrand RC3 Receptacle Replacement User Manual

Rc3, rc7 & rc4 receptacle replacement, Installation instructions

Advertising
background image

RC3, RC7 & RC4
Receptacle Replacement

INSTALLATION INSTRUCTIONS

Installation Instruction No.: 1 003 786R1 – Updated October 2003

Products Covered: RC37REC, RC4REC2, RC37REC-25 and RC4REC2-25

IMPORTANT: Please read all instructions

before beginning.

Walker

®

electrical systems conform to and should be properly

grounded in compliance with requirements of the current National
Electrical Code or codes administered by local authorities.

All electrical products may present a possible shock or fire
hazard if improperly installed or used. Walker electrical products
may bear the mark as UL Listed and/or Classified and should
be installed in conformance with current local and/or the National
Electrical Code.

Step 1 Remove junction box cover and disconnect wires.

Step 2 Remove slide holder and scrub water gasket.

Step 3 Use screwdriver to disengage snap fingers. Move

screwdriver to the outside and pull up. Repeat on
the other side of the receptacle.

Step 4 Remove receptacle from assembly.

For RC3TC & RC7TC Series Devices

For use with: RC3TC, RC7TC, and RC4TC Series Poke-Thru Devices

CAUTION:

De-energize circuit before removing
junction box cover.

Advertising
This manual is related to the following products: