Installation and operating instructions – Louroe Electronics AOPSP-PB User Manual

Page 2

Advertising
background image

WIRING CONNECTION TO SPEAKER AND MICROPHONE OF AOPSP-PB

Connect the two wires (black and green) attached to Call Button Switch to the contacts of the
receiving device, using wire nuts and 22 gauge stranded wire. Refer to the receiving device
manufacturers instructions for proper connection.

Page 2 of 4

LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

INSTALLATION AND OPERATING INSTRUCTIONS

WIRING CONNECTION TO AOPSP-PB CALL BUTTON

aopsp-pb_inst 3/15

Drill an opening top, bottom or back side
of backbox for passing wiring or for
connecting conduit.

block marked A, B, C, SP

A = 12Vdc power

B = Audio output
C = Ground (bare wire)
SP = Speaker Connection

Bring one end of recommended cable and connect as follows:

Located on the bottom right side of PC board is a 4-pin terminal

1) Connect RED wire to terminal marked “B”
2) Connect BLACK wire to terminal marked “C” (together with bare wire)
3) Connect BARE wire to terminal marked “C“
4) Connect WHITE wire to terminal marked “SP“
5) No connection on terminal “A”

WIRING REQUIREMENTS

3 Conductor consisting of:

+

2 Conductor shielded, 20 gauge
with 22 gauge drain

+

1 Conductor unshielded, 20 gauge

All in the same jacket

WIRING CONNECTION TO IP CAMERA OR DVR

POWER CONNECTION

Bring the other end of the cable to connector that matches the audio input
and outputs of the receiving devices
1) RED (positive audio) and BARE (ground) are soldered to the audio

connector (RCA, 3.5mm Mono or Stereo plugs). This connector goes
to the Audio input of the receiving device (IP Camera, DVR, etc)

2) WHITE (positive audio) and BLACK (ground) are soldered to the another

audio connector (RCA, 3.5mm Mono or Stereo plugs. This connector
goes to the Audio output of the receiving device (IP Camera, DVR,
etc).

The unit has a 2-pin terminal block for power connections marked 12Vdc
1) Connect the positive 12Vdc of the power supply (AD-1) to the terminal

marked +

2) Connect the negative or ground of the power supply to terminal marked

GRD

WIRING CONNECTION TO AOP-SP-PB

See connections on the next page

Advertising