Interconnection diagram, Installation and operating instructions, Aop-xd is not used for this application – Louroe Electronics AOPSP-PB User Manual

Page 3: Wiring requirements

Advertising
background image

INTERCONNECTION DIAGRAM

CONNECTING LOUROE MODEL AOPSP-PB

DIRECTLY TO AN IP CAMERA, DVR,

VIDEO SERVER, ETC. USING 3-COND. SHIELDED CABLE

EXT
MIC

SPKR

+12Vdc

AUDIO
OUT

AUDIO

IN

A B C

TALKBACK
ADJUST

MIC

ADJUST

C

A

SP

B

LOUROE MODEL AOPSP-PB

WHITE (SP)

BLACK (C)

(C) BARE

(B) RED

TO AUDIO OUT OF IP CAMERA, DVR, ETC.

TO AUDIO IN OF IP CAMERA, DVR, ETC.

NOTE: BLACK AND BARE WIRES ARE COMMON GROUND

BARE (C)

BLACK (C)

RED (B)

4-PIN TERMINAL BLOCK IDENTIFIER OF AOPSP-PB (A,B,C,SP)

(

) B = Audio Output

(

) C = Ground (audio) and Ground (speaker) (black wire)

(

) SP = Speaker output

A = not used with this application

red

bare
white

West Penn 358
or equivalent

C

A

SP

B

WHITE (SP)

Audio Out

Audio Out

Audio In

Audio In

Bare Wire

Red Wire

RCA CONNECTION

3.5mm MONO CONNECTION

3.5mm STEREO CONNECTION

White Wire

Black Wire

Black Wire

White Wire

Red Wire

Bare Wire

M
O

N

O

S

T

E
R
E

O

Audio Out

Audio In

Red Wire

Black Wire

White Wire

Bare Wire

WIRING REQUIREMENTS

3 Conductor consisting of:

+

2 Conductor shielded, 20 gauge
with 22 gauge drain

+

1 Conductor unshielded, 20 gauge

All in the same jacket

CALL

BUTTON

ELECTRET

CONDENSER

MICROPHONE

TO SWITCH CLOSURE OF

AUDIO RECEIVING DEVICE

(refer to manufacturer’s

instructions for connection)

EXT
MIC

SPKR

AUDIO
OUT

AUDIO

IN

AOP-XD is not used for this application.

+12Vdc,500mA power required
(AD-1 power supply included)
Connect to this 2-pin terminal block

12 Vdc power is required to connect the AOP-SP-E directly to
an IP camera or DVR such as AD-1 power supply.
Positive 12Vdc connects to terminal marked “+”
Negative 12 Vdc or ground

connects to terminal marked “GND”

(wire with white stripes)

+12Vdc

+

GND

Page 3 of 4

LOUROE ELECTRONICS® 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

INSTALLATION AND OPERATING INSTRUCTIONS

WIRE

NUT

WIRE

NUT

aopsp-pb_inst 3/15