INPUT CONNECTIONS TO MLA-8

MICROPHONE CONNECTION:

At the top part of the PC board are 8 Terminal blocks marked 1 through 8 (for 8 zones). Each terminal

block has 5 Pins marked - A, B, C, SP and G . Bring in wire from remote microphone (or
speaker/microphone) and connect as follows:

Pin A (12 Vdc) from remote microphone to Pin A of MIC 1 terminal block of MLA-8(red wire)
Pin B (audio) from remote microphone to Pin B of MIC 1 terminal block of MLA-8(black wire)
Pin C (ground) from remote microphone to Pin C of MIC 1 terminal block of MLA-8.(bare wire)

Repeat connections for ZONE 2 to ZONE 8.

Use 2 Cond Shielded cable (see page1) if only microphones are to be connected.

SPEAKER CONNECTION (used only if microphone/speaker units are being connected):

Green wire from speaker to Pin SP of MIC1 terminal block of MLA-8
White wire from speaker to Pin G of MIC 1 terminal block of MLA-8

Repeat this connections for the rest of the zones.

Use 4 Cond shielded cable such as West Penn 356 (see page1) if microphone/speaker units are used.

POWER REQUIREMENTS

For Cable runs 1,000’ and under

If the total distance from the remote microphone (or speaker/microphone) to the MLA-8 Mixer and on to the

Louroe Base Station is under 1,000 ft., the MLA-8 will receive 12Vdc power from the base station. No
power is required at the MLA-8.

For Cable runs 1,000 to 5,000’

If cable run between MLA-8 and Louroe Base Station is over 1,000 ft and up to 5,000 ft, 12 Vdc power is

required. An input jack for power is located on MLA-8 chassis. For this length of run, MLA-8 should be
mounted within 1,000’ of the microphone.

IMPORTANT NOTE

1. If Model MLA-8 Mixer is to be powered for a cable run between 1,000 ft. and 5,000 ft. from the Louroe base

station, do not use terminal “A” connection between the MLA-8 and the Louroe base station.

2 For cable runs that exceed 1000 ft or up to 5,000 ft, MLA-8 Mixer should not be positioned more then 1,000

ft. from the Louroe microphone or speaker/microphone.

NOTE: If alternate power supply is

used, DO NOT USE POWER
SUPPLY IN BASE STATION

Page 2 of 8

LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

®

INSTALLATION AND OPERATING INSTRUCTIONS

mla_6/8_inst_3/15

Advertising