Function – LSC Lighting MINIM User Manual

Page 26

Advertising
background image

Utilities

MINIM Operator Manual V1.0

Page 22 of 27

LSC Lighting Systems (Aust) Pty. Ltd.

LOAD SHOW FROM MEMORY MODULE

When you load a show from the Memory Module, you replace the entire contents of the MINIM’s
memory with the show data on the Memory Module. This includes all Scenes and Chases.

To load a show, plug-in the Memory Module to the ”COMMS PORT”. If a Memory Module is not
plugged in or if the Memory Module is empty, then the MINIM will detect this and not flash the

[F/A]

(load) LED.

Ensure the MINIM is in MEMORY RUN mode

Press and hold

[function]

then press and hold

[F/A]

(load) at the same time, for a period of 5

seconds, then release both.

The MINIM will interrogate the Memory Module to see what shows exist. The show numbers saved
will be flashed on the corresponding Red Bank LEDs.

Press

[F/A]

(show number) to load the selected show.

Loading a show takes a few moments. A progress meter is displayed on the Edit Value Scale
LEDs. During this time normal operation of the MINIM is not possible.

WARNING: Once a load from the Memory Module is initiated, the current contents of the
MINIM’s memory will be erased and cannot be recovered.



Note: If a save or load error occurs, the MINIM will stop all data transfer, flash all LED’s on
the front panel for 5 seconds and then resume to its state prior to the save or load function.
Try the save or load again and if the same problem persists, then LSC recommends
changing the Memory Module with another. If data errors still occur, then contact LSC or
your nearest service agent.

Advertising