MBM Corporation OMR User Manual

Installation instruction omr-kit

Advertising
background image

T09137

Page 1

Preparation

1. Switch off the main power switch on the Powerpack (power supply).
2. Disconnect the power cord and communication cable/cables.
3. Remove all 11 plastic plugs (1).
4. Lift the cover out and remove the ground wire from the cover.
5. Remove the cover.
6. Use a small screwdriver to move the securing plate (2) downwards.
7. Remove the gas springs (3) on both sides and lower the accumulator box.

CAUTION: Whitout the gas springs, the accumulating station will fall down to it´s transport position.

8. From the rear, remove the four screws (4) using a 10 mm key.
9. Lift the Model 49 (5) from the stand.
10. Lift the accumulating box (6) from the stand.
11. Cut the tie-wraps (7) and move the ribbon cable from the mounting bracket.

7

Installation Instruction OMR-kit

4

5

6

2

3

1

July 2001

Part No. 49026

Advertising