Page 4

1. Open the wiring covers and place the cable from the reader head inside the wiring

cover. The cable leght between the wiring cover and the reader head must not be less
than 250 mm.

2. Let the cable enter the Model 49 through the hole next to the outside part of the insert

front guide (1).

3. Measure the correct length by placing the cable along the sides and then cut it off.

Strip the ends approx 5 mm.

Do not cut the shield of the cable, used as earth connection.

4. Place the cable along the side and secure with tie-wraps.
5. Put the grey latch on the amplifier in the open position (2) and insert the cable parts in

the holes (3) as marked on both sides of the amplifier.

6. Close the latch (4), mount the cover (5).