MBM Corporation TRIUMPH 6655 User Manual

Page 20

Advertising
background image

- 20 -

IDEAL 4855

IDEAL 5255

IDEAL 6655

1

6

4
5

7

2
1

3

9

8

8

T

Operating elements

A

- Safety two-handed control system

Pre-clamping and cutting

B

- Overload switch

(blade drive/clamp drive/

backgauge drive)

C

- Backgauge control

D

- Main switch

E

- Hand-wheel for backgauge setting

F

- Key switch

G

- Backgauge

H

- Side lay left and right

I

- Front safety guard

Operation

Start machine

Main switch

D

to position "I", insert the key

F

for the control panel and turn to the right.

Start screen appears

The following functions are changeable:

Brightness

CM/INCH

Touchtone ON/OFF

Language

Press START

J

backgauge

G

moves to

the rear and searches for the reference

position, wait until a measurement

is shown in the display

C

IDEAL 4855 = 45 cm, 17.72 inches

IDEAL 5255 = 52 cm, 20.47 inches

IDEAL 6655 = 61 cm, 24.02 inches

The DIN measurements in cm

(A3, A4, A5, A6) and in inch (LD, LG, LT, hLT)

are recallable with the respective buttons.

Warning!

Before storing or cutting a measurement

please check if the correct measurement scale

(cm or inch) see above is stored.

For information on how to store see picture

below left. Is shown on the screen see

K

.

After 30 minutes the screen switches to

energy-saving mode

The screen is reactivated by touching the

keypad area

L

.

Advertising
This manual is related to the following products: