Aao(name), Aao(name) -8 – Measurement Computing CB-7080 User Manual

Page 26

Advertising
background image

CB-7080 & CB-7080D Counter/Timer User's Guide

~AAO(name)

2-8

~AAO(name)

Description

: Sets the module name.

Syntax

: ~AAO(name)[chk](cr)

~

A delimiter character

AA

2-character HEX module address, from 00 to FF

(name)

4-character/5-character module name

[chk]

2-character checksum. If checksum is disabled, no [chk]

(cr)

0x0D

Response

:

Valid response

!AA[chk](cr)

invalid response

?AA[chk](cr)

No response

Syntax error, communication error or address error

!

A delimiter character indicating a valid response

?

A delimiter character indicating an invalid response

AA

2-character HEX module address

[chk]

2-character checksum. If checksum is disabled, no [chk].

(cr)

0x0D

Examples

:

Change module name from 7080 to 8080

command:

$01M(cr)

response:

!017080(cr)

command:

~01O8080(cr)

response:

!01(cr)

Change module name from 7080D to 8080D

command:

$01M(cr)

response:

!017080D(cr)

command:

~01O8080D(cr)

response:

!01(cr)

Note

This command was designed for OEM/ODM users. You can use it to change the module name for other
purposes.

Advertising