CB-7080 & CB-7080D Counter/Timer User's Guide

@AAEAT

2-40

@AAEAT

Description

: Enable the counter alarm (for alarm-mode 1). Refer to "

Counter alarm mode selection

" for more

information.

Syntax

: @AAEAT[chk](cr)

@

A delimiter character

AA

2-character HEX module address, from 00 to FF

T=M

momentary alarm, T=L  latch alarm

[chk]

2-character checksum. If checksum is disabled, no [chk]

(cr)

0x0D

Response

:

Valid response

!AA[chk](cr)

Invalid response

?AA[chk](cr)

no response

Syntax error, communication error or address error

!

A delimiter character indicating a valid response

?

A delimiter character indicating an invalid response

AA

2-character HEX module address

[chk]

2-character checksum. If checksum is disabled, no [chk]

(cr)

0x0D

Examples

:

Latch alarm for module 1:

command:

@01EAL(cr)

response:

!01(cr)

Momentary alarm for module 2:

command:

@02EAM(cr)

response:

!02(cr)

Note:

If the alarm is enabled, D/O 0 and D/O 1 will always be controlled by the module. Therefore the following
D/O conditions will exist:

- Power-on value is changed to hi/lo condition immediately.

- The @AADO0D command is ignored.