Using Periodic Interrupts

If the clock shall generate periodic interrupts, three bytes must be written to the dual
port RAM:

Interrupt Vector

After power up, this byte is set to 0Fh. The user must take care to set up the vector
number corresponding to the system's exception vector assignments.

Interrupt Level

This byte is set to 00h after power up. The user must supply the desired interrupt level
(01h..07h).

Interrupt Rate

The contents of this byte reflects the rate of interrupts generated by the board. After
power up, its value is 00h. Valid codes are given below:

00h

no interrupt

01h

once ever 10 milliseconds

02h

once every 100 milliseconds

03h

once every second

04h

on every 10 seconds

05h

once every minute

06h

once every 10 minutes

07h

once every hours

others:

(reserved)