Remove screw.

Do not discard.

Rotate temperature

A.

stop fully anti-

clockwise

If temp ≤ 46°C

B.

If temp > 46°C

Adjust (see

commissioning)

COMMISSIONING -

The Tahi thermostatic mixer valve is factory set to the required temperature.

Check the valve after installation to ensure it operates at the correct outlet

temperature.

Prior to commissioning the Tahi thermostatic mixing valve check the following:

The designation of the thermostatic mixing valve matches the application.

The supply pressures are within the valves operating range.

The supply temperatures are within the valves operating range.

Isolating valves (and strainers preferred) are installed.

REMOVE MAXIMUM TEMPERATURE STOP

Remove screw.

A.

Do not discard.
Rotate clockwise

B.

until water temp

= 38°C

NOTE - Use of supply

line or zone strainers is

strongly recomended.

1

MOUNT

PARALLEL TO

WALL LINING

2

P < 1000 kPa/10 bar

(Test pressure must not

exceed 1000 kPa/10 bar)

CHECK WATERTIGHTNESS

3

FIT WALL LINING AND REMOVE DUST COVER

USE PROVIDED

TEMPLATE FOR

ACCURATE HOLE

DIMENSIONS.

6mm MAX

6mm MAX

4

Wall lining

Tiles

TRIM FLUSH AND SEAL WITH SILICON

5

CHECK MAX OUTLET TEMPERATURE

6

FIT TRIM COMPONENTS

7

SET WATER TEMP TO 38°C

8

ASSEMBLE DIAL GUIDE AND DIAL

Dial

guide

Dial

DOWNWARD ORIENTIATION

OF BUTTON CRITICAL

9

ASSEMBLE HEIGHT ADJUSTOR

Hold dial

A.

hard against

faceplate.
Wind depth

B.

adjustor into

dial. Stop when

you feel dial

starting to push

away from the

faceplate

Faceplate

Depth adjustor

8mm Allen key

Dial

If depth adjustor

C.

protrudes past

the front face of

the dial; Remove

the depth

adjustor and

trim at midpoint

(cut in half).

Reassemble as

per steps 9: A

and B

10

Insert and tighten

A.

screw using

2.5mm Allen

key (finger tight

only) to fix dial

position.
Fit cap (force

B.

required)

Tip: Insert dot end

of cap first

HOLD DIAL TO STOP

ROTATION WHILST

TIGHTENING.

FIT DIAL CAP

Note: Dot orientation on dial

cap is at top (opposite dial

button).

1

2

TEMPERATURE

MUST NOT

EXCEED 46°C

ADJUST TEMPERATURE TO

DESIRED MAXIMUM.

3

REASSEMBLE MAXIMUM

TEMPERATURE STOP

Assemble with faces

aligned as shown

Note: Do not Rotate

cartridge control knob

while assembling

Maximum temperature

stop

Maximum temperature stop

x 2 (long screws)

x 2 (short screws)

x 2 (Allen screws)

VER

TICAL

=

=

96-116mm

OPTIMUM = 106mm

=

=

PARALLEL

MOUNT MIXER BODY IN WALL CAVITY

NOTE - Levers to be

inserted from bottom

as shown in diagrams

A and B

NOTE - Locating

feature

Trim

Depth Adjustor

Dial

Maximum temperature stop

Cartridge control knob

Wall lining

Wall lining

A.

B.

Advertising