Alignment Verification with Connector LEDs

IM-Mercury_II_6000 Series Rev. 1

Page 19

©2014 MicroE Systems

Mercury

II

6000 Series Encoders

Installation Manual and Reference Guide

6.0 Alignment Verification with Connector LEDs

Once the encoder is aligned and calibrated using the alignment tool, alignment can be visually
verified using the LED indicators on the MII6000 sensor’s connector.

Sensor Connector display (shown during normal operation):

Color Codes for Indicators

Mercury II Sensor Connectors

LED Indicators

– Signal Strength

Color

Signal Strength

Green

Optimal

Yellow

Marginal

Red

Bad

Purple

Saturated

Mercury II Sensor Connectors

LED Indicators

– Limit/Index Markers

Color

Limit/Index Mark

Green

Over Index Mark

Blue

Over Left Limit Mark

Red

Over Right Limit Mark

None

Not Over Any Mark

Signal Level LED indicates
signal strength of main track
(green is optimal)

Limit/Index LED Indicates presence of
left limit mark, right limit mark, or index
mark (no color indicates sensor not
positioned over any marks)