11

Ports

RJ-45 ports (Auto MDI/MDIX): The RJ-45 ports are auto-sensing for

10Base-T, 100Base-TX or 1000Base-T devices connections. Auto

MDI/MDIX means that you can connect to another switch or workstation

without changing straight through or crossover cabling. See figures as

below for straight through and crossover cable schematic.

RJ-45 Pin Assignments

Pin Number

Assignment

1

Tx+

2

Tx-

3

Rx+

6

Rx-

Note

“+” and “-” signs represent the polarity of the wires that make up

each wire pair.


All ports on this industrial switch converter support automatic

MDI/MDI-X operation, you can use straight-through cables (See Figure

below) for all network connections to PCs or servers, or to other

switches or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one

end of the cable, are connected straight through to pins 1, 2, 3 and 6 at

the other end of the cable. The table below shows the 10BASE-T/

100BASE-TX /1000Base-T MDI and MDI-X port pin outs.

Pin MDI-X

Signal Name

MDI Signal Name

1

Receive Data plus (RD+)

Transmit Data plus (TD+)

2

Receive Data minus (RD-)

Transmit Data minus (TD-)

3

Transmit Data plus (TD+)

Receive Data plus (RD+)

6

Transmit Data minus (TD-)

Receive Data minus (RD-)