4. Power on the Industrial switch converter. How to wire the power; please

refer to the Wiring the Power Inputs section. The power LED on the

Industrial switch converter will light up. Please refer to the LED Indicators

section for meaning of LED lights.

5. Prepare the twisted-pair, straight through Category 5 cable for Ethernet

connection.

6. Insert one side of Category 5e or above cables into the Industrial switch

converter Ethernet port (RJ-45 port) and another side of category 5e or

above cables to the network devices’ Ethernet port (RJ-45 port), e.g.

switch, PC or Server. The UTP port (RJ-45) LED on the Industrial switch

converter will light up when the cable connected with the network device.

Please refer to the LED Indicators section for LED light meaning.

Note

Be sure the connected network devices support MDI/MDI-X. If it does

not support, then use the crossover category 5e/above cable.

7. When all connections are all set and LED lights all show in normal, the

installation is complete.