Sensor adjustment with Teach-in procedure

Set detect point

Place object at position 

Press push-button for about

3 s until LEDs flash

simultaneously

both LEDs:

flash
mutually

Press push-button for

about 1 s

Set window mode

Place object at position 

Press push-button for about

3 s until LEDs flash

simultaneously

both LEDs:

Place object at position ¡

Press push-button for

about 1 s

flash
mutually

Set two way reflective

barrier

Set NOC/NCC

Enable/disable Teach-in

push-button

Switch off power supply

Place object at position 

Press push-button for about

3 s until LEDs flash

simultaneously

Press button for about 13 s

until LEDs flash

mutually

both LEDs:

flash
mutually

Press push-button for

about 10 s

green LED:

yellow LED:

To change output characte-

ristic press push-button

for about 1 s

While pressing the push-

button switch on power

supply

Keep push-button pressed

for about 3 s until both

LEDs flash simultaneously

flashes

on: NOC
off: NCC

green LED:

yellow LED:

flashes

on: push-button
enabled
off: push-button
disabled

To enable/disable Teach-in

press push-button

for about 1 s

Reset to factory setting

Switch off power supply

While pressing the push-

button switch on power

supply

Keep push-button pressed

for about 13 s until both

LEDs stop flashing

Normal operating mode

Wait for 10 s

Wait for 10 s

Normal operating mode

Operating Instructions

zws-15/CD/QS

zws-15/CE/QS

zws-24/CD/QS

zws-24/CE/QS

zws-25/CD/QS

zws-25/CE/QS

zws-70/CD/QS

zws-70/CE/QS

Ultrasonic proximity switch with
one switched output

Product Description
The zws sensor offers a non-contact
measurement of the distance to an
object which must be positioned

Ultrasonic Sensors

within the sensor’s detection zone.
The switched output is set in depen-
dence of the adjusted detect dis-
tance.
Via the push-button, the detect dis-
tance and operating mode can be
adjusted (teach-in). Two LEDs indi-
cate operation and the state of the
switched output.

Safety Notes



Read the operating instructions
prior to start-up.



Connection, installation and
adjustment works may only be
carried out by expert personnel.



No safety component in
accordance with the EU Machine
Directive

Proper use
zws ultrasonic sensors are used for
non-contact detection of objects.

Installation



Mount the sensor at the installa-
tion site with the aid of the
enclosed mounting plate.
Maximum torque: 0,5 Nm

Fig. 1: Attachment with mounting plate



Connect a connection cable to the
M8 device plug.



Avoid mechanical load on the con-

nector.


Fig. 2: Pin assignment with view onto sensor

plug and colour coding of the
microsonic connection cable

Start-Up



Connect the power supply.



Carry out the adjustment
in accordance with the diagram.

Factory Setting



Operation with one detect point



Switched output on NOC



Detect points at operating range

1
3

colour

+U

B

-U

B

brown
blue

4
2

D

Sync

black
white

1

4

3

2

Operating modes
Three operating modes are available
for the switched output:



Operation with one detect point

The switched output is set if the ob-
ject falls below the set detect point.



Window mode

The switched output is set if the ob-
ject is within the set window mar-
gins.



Two-way reflective barrier

The switched output is set if the ob-
ject is between sensor and reflector.

Synchronization
You can synchronize as many sensors
as you like.



Apply a square-wave signal to the
sync-input with pulse width t

i

and

repetition rate t

p

(Fig.3 and

technical data).

A high level on the sync-input will
deactivate the sensor.

Fig.3: External synchronization signal

Checking operation mode



In normal mode shortly press the
push-button.

The green LED stops shining for one
second, then it will show the current
operating mode:
1 x flashing = operation with one

switching point

2 x flashing = window mode
3 x flashing = reflective barrier

After a break of 3 s the green LED
shows the output function:
1 x flashing = NOC
2 x flashing = NCC

Maintenance
microsonic sensors are maintenance-
free. In case of excess caked-on dirt
we recommend cleaning the white
sensor surface

Notes



The zws sensor has a blind zone,
within which distance measure-
ments are not possible.



In the normal operating mode, an il-
luminated yellow LED signals the
switched output is switched
through.



The standard sensor has no tempe-
rature compensation.



If the object to be sensed moves
into the detection area from the
side, the switching distance should
be set 8-10 % further than the de-
sired switch point to obtain a reli-
able object detection.
If the object moves towards the
sensor (e.g. level control) the detect
point can be taught to the actual
distance at which the sensor has to
switch the output.

Sensor disabled

Sensor disabled

Start

+U

B

-U

B

t

i

t

p

Set switched output

Further settings