POSaStaRt COnnECtiOnS

The Cobramatic and Cobra II Wire Feeders each have, a single black 14 ga. wire with an

alligator clip, extending from the back connected to the main board. This is the voltage sens-

ing lead for the PosaStart circuit. In order for PosaStart to properly work, this lead must be

connected to the welding GROUND.

Typically, most power supplies will accept

the PosaStart lead connected to either the

work GROUND lug on their front panel or the

GROUND clamp.
However, some newer types of inverters must

have this PosaStart lead connected directly to

the GROUND lug.
Newer Cobramatic units have a CC/CV config-

uration switch on the main board. Consult the

owners manual in order to properly configure

this switch.

PosaStart Configuration

Switch on Cobramatic

Main Board