MMD PowerPro Inverter Generators • IGR3000 (041715)

MMD PowerPro Inverter Generators • IGR3000 (041715)

Page 22

Page 23

Air Conditioning Operation

n

For best results, the SMART throttle switche should be in the off position.

n

Bring the generator to normal operating temperature before applying the air

conditioning load. Always allow a 2 minute wait period when manually cycling an

air conditioner off and on.

n

A longer wait period may be required under unusually hot weather conditions.

n

Additionally, all other loads should be turned off until the air conditioner has

started and is performing normally. It is also important to follow the air conditioner

manufacturer's instructions for starting and restarting for proper operation.

n

Some air conditioner manufacturers offer a start capacitor or rapid start kit. The

lack of a start capacitor can cause the air conditioner to draw too high a starting

current and overload the generators. Contact your air conditioner dealer if you

consistently have problems starting your air conditioner.

n

This generator is not generally recommended for air conditioners exceeding

13,500 BTUs.

Low oil alarm system

The low oil alarm system is designed to prevent engine

damage caused by an insufficient amount of oil in

the crankcase. Before the oil level in the crankcase

falls below a safe limit, the low oil alarm system will

automatically shut down the engine (the engine switch

will remain in the ON position).
If the low oil alarm system shuts down the engine the red

low oil alarm indictor light will come on when you operate

the starter, and the engine will not run. If this occurs,

search for any oil leaks. Add engine oil to resume normal operation.

SMART Throttle
When the SMART throttle is placed in

the on position, engine speed is kept at

idle automatically when the electrical

load is disconnected and returns to the

proper speed required by the electrical

load when the load is reconnected.

The engine speed varies according to the amount of load applied to the generator.

Placing the smart throttle in the on position is recommended to minimize fuel

consumption and engine noise while in operation.

n

The Smart-throttle system does not operate efficiently if the electrical appliance

will be used in a rapid on-off or low-to-high rpm mode.

n

When high electrical loads are connected simultaneously, turn the Smart-throttle

switch to the OFF position to reduce voltage fluctuation or shutdown.

n

In DC operation, turn the Smart-throttle switch to the OFF position. When the

Smart throttle is in the off position, the engine runs at rated load RPM.

SMART-

THROTTLE

SWITCH

ON

OFF