Operation – MMD Equipment 400S-6B1 User Manual

Page 24

Advertising
background image

4. Operation

4-5

4.3.5 Drain Water Sedimenter

Check if the red float“1”in the water sedimenter rises up to
the water drain level“2”, then drain water if it is near the
drain level.

(Draining procedure)

Loosen the drain plug“3”and drain out condensed water
inside.

After draining condensed water, close the drain plug“3”
without fail.




4.3.6 Check Fuel level

Fire prevention

Do not, under any circumstance, smoke cigarettes or light

matches during fueling.

Fuel is extremely flammable and dangerous. It therefore, could

catch fire should it flame or other sources of ignition be brought

near fuel.

Refuel only after stopping the engine, and never leave an open

fuel can near the machine. Do not spill. It could cause a fire.

When it is spilt, wipe it up completely.

Refilling fuel tank should be done in an outdoor well-ventilated

place.

D004

Choose appropriate fuel

Be sure to use diesel fuel oil for diesel engine use.

(Using other oil will cause low power or damage to the engine.)

Check fuel level gauge before operation. Replenish enough fuel to prevent fuel shortage during
operation, if the level is low.

When refueling, fill a fuel tank up to the base of fuel filler port. Never overfill fuel because it
may cause fuel leakage.

Be sure to fasten the fuel tank cap firmly after replenishment. If fuel is spilt, wipe it up
completely.




2

1

3

A020404