The Venting Graph

Measure the vertical height from the fireplace hearth to the centre of the

termination and the horizontal run from the fireplace flue collar to the wall

flange of the termination. Plot on the Venting Graph Figure 11 with an 'X'.

If the 'X' falls on or above the top boundary of the shaded area, the

installation is acceptable.
Example A: (Acceptable Installation)

If the vertical dimension from the hearth is 120" and the horizontal

run to the wall flange of the vent termination is 138", this would be

an acceptable installation.

Example B: (Unacceptable Installation)

If the vertical dimension from the hearth is 48" and the horizontal

run to the wall flange of the vent termination is 96", this would

NOT be an acceptable installation.

Example C: (Unacceptable Installation)

If the vertical dimension from the floor of the fireplace is 72" and

the horizontal run to the wall flange of the vent termination is 120",

this would NOT be an acceptable installation.

Figure 11. HL42DF*-ST Top Vent Venting Graph for wall mounted terminations.

Figure 11a. Top Vented, wall mounted installation with one 90° bend. The vent

run must comply with Venting Graph for Top vent, wall mounted terminations,

Figure 11.

Figure 11b. Top Vented, wall mounted Multi-elbow installation. See Venting

Graph for Top vent, wall mounted terminations, Figure 11.

Section 3-3-1: Venting Layout: Wall Mounted Termination

Selection of components and details of venting layout should

adhere to the following guidelines:

„

Vent terminations must not be recessed in walls or siding.

„

For Heat Shield requirements see Section 3-3-3 on page 15.

„

Once the proposed venting layout has been determined refer to

Figure 11 or 12 to ensure the layout is acceptable.

Notes Wall Mounted Terminations: TOP VENT

„

All measurements for vertical or horizontal runs are measured

from center of the vent pipe.

„

Venting runs must fall within the limits set by the venting graph,

see Figure 11.

50”

36” NG

12” LP

Unacceptable vent run

within shaded area.

Acceptable vent run

within non-shaded area.

A

B

C

If your isnstallation does not fall

within the venting parameters,

please contact local Montigo dealer

for Power Venting options.

Heat Shield

Flex or Rigid

Insulated Sleeve

CRS101

Termination

Exterior

Wall

Hearth

36" MAX NG

12" MAX LP

50"

Solid Section

Flex Section

Hearth

Heat

Shield

Termination

Exterior

Wa

ll

.

150" MAX

Solid Sectio

Flex Section

Hearth

Exterior

Wa

ll

Termination

Heat

Shield

126"

30" MAX

Figure 11c. Top Vented, wall mounted Retracted Multi-elbow installation. See

Venting Graph for Top vent, wall mounted terminations, Figure 11.