H*42DF ST Indoor Gas Fireplace

Page 15

XG0237 - 150204.1

Installation

Figure 12. Side Vent Venting Graph for wall mounted terminations.

Figure 12a Side Vented, wall mounted Multi-elbow termination installation.

The vent run must comply with the Venting Graph for Side vent, wall mounted

terminations, Figure 12.

Notes Wall Mounted Terminations: SIDE VENT

„

SIDE VENTED INSTALLATIONS MUST BE MULTI ELBOW

„

SIDE VENTED INSTALLATIONS MAY NOT TERMINATE

STRAIGHT THROUGH THE WALL.

„

All dimension lengths for vertical or horizontal runs are measured

from center of the vent pipe.

„

Venting runs must fall within the limits set by the venting graphs,

see Figure 12.

„

Fireplace must be converted to Side Vent configuration prior to

running vent, see Figure 7 and 7a.

The Venting Graph

Measure the vertical height from the fireplace hearth to the centre of the

termination and the horizontal run from the fireplace flue collar to the wall

flange of the termination. Plot on the Venting Graph Figure 12 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the

installation is acceptable.
Example A: (Acceptable Installation)

If the vertical dimension from the hearth is 120" and the horizontal

run to the wall flange of the vent termination is 138", this would be

an acceptable installation.

Example B: (Unacceptable Installation)

If the vertical dimension from the hearth is 48" and the horizontal

run to the wall flange of the vent termination is 96", this would be

this would NOT be an acceptable installation.

Example C: (Unacceptable Installation)

If the vertical dimension from the floor of the fireplace is 72" and

the horizontal run to the wall flange of the vent termination is 120",
this would NOT be an acceptable installation.

30” Max.

12”

Max.

Flex or Rigid

Section

14 1/2”

Min.

Hearth

37"

52" Min

52”

42”

Unacceptable vent run

within shaded area.

Acceptable vent run

within non-shaded area.

A

B

C

If your isnstallation does not fall

within the venting parameters,

please contact local Montigo dealer

for Power Venting options.

Note: Images are shown without screens for clarity purposes. However,

your fireplace should not be operated without proper installation of

screens.