Section 4: Installing the Gas Line

Section 5: Electrical Connection

Figure6.Gas Inlet Supply location, (left-hand side of fireplace facing indoor face).

Fuel Consumption

Verify that your fireplace is compatible with your available gas type. (Natural Gas

or Propane shown by "N" or "L" in your model number
If gas type is not compatible, contact your local Montigo representative to purchase

a conversion kit.
Conversion kits must be installed by a qualified service technician.

Gas Pressure

Optimum appliance performance requires proper input pressures.
Gas line sizing requirements will be determined in ANSI 223.1 National Fuel Gas

Code in the USA and CAN/CGA B149 in Canada.

Pressure requirements:

The manifold outlet pressure is set from the factory to the appropriate pressure but

should be verified.
To check pressures, control valves have a provision to remove a 1/8” N.PT. plug to

be fitted with a hose barb.
Montigo requires a service shut off valve be located in an accessible location to

isolate the gas supply.
Only install gas shut-off valves approved for use by the state, province, or other

governing body in which the fireplace is being installed.

GAS CONNECTION

The gas connection is located on the left side of the fireplace looking at the indoor

face of the unit.
Connect this line to a service shut of valve as per local code.
Make sure that the gas line as well as the shut of valve will be rated for 75,000 BTU
Purge all air out of the gas line prior to start up.
Flexible gas connectors must not exceed 3 feet in length, unless allowable within

local regulations.
Connect incoming gas line to the 1/2"or 3/8" gas inlet port.
Check appliance connection, valve and valve train under normal operating pressure

with a commercially available leak check solution.
DONOTUSEAFLAMEOFANYKINDTOTESTFORLEAKS.

Pressure Requirements

Gas Pressure

Natural Gas

Propane

Minimum Inlet Pressure

5.5" W.C.

11" W.C.

Manifold Presure

3.5" W.C.

10" W.C.

After gas line is connected, each appliance connection, valve and valve train MUST

be checked while under normal operating pressure with either a Liquid Solution, or

Leak Detection Device, to locate any source of leak. Tighten any areas where

bubbling appears or a leak is detected until bubbling stops completely or leak is no

longer detected. DO NOT use a flame of any kind to test for leaks. A fire or explosion

will occur, causing serious injusy, property damage or death.

DANGER

When pressure testing the fireplace, Gas line, and input system follow the appropriate

local codes or your area. DO NOT connect the fireplace to pressures in excess of

1/2lb. This will damage the gas control valve.

NOTICE

We recommend careful consideration be given to the effects of elevated mantel

temperatures which may be in excess of product design, for example: candles, plastic

or pictures. This can cause melting, deformation, discoloration or premature failure of

T.V. radio, and other electronic components.

CAUTION

When covering the upper metal portion of the fireplace, (as shown, Fig.16)

with a non-combustible material, Please Note: The decorative facing

materials may be subject to temperatures in excess of 250° F. This should

be considered when selecting facing materials.

CAUTION

Connect 115 Volt 12 Amp power supply to the

connection box located on the right side bottom corner of

this fireplace.

There is 25 Feet of low voltage wire coiled up on the

same side of this fireplace.

Run this low voltage wire to an on / off switch at a

location of your choice.

If this wire is inadequate in length you may replace this

wire with any Number 18 gage solid or stranded wire in

any length.

Do not splice these wires. Run a new wire directly from

the control board to the switch location.

Caution: Do not apply any power to these two wires.