Montigo HFK-Series Cross-Flow Blower User Manual

Installing the hfk-series cross-flow blower, Caution, This kit should be installed by a qualified person

Advertising
background image

Burner Tray Gasket

17

This kit should be installed by a qualified person.

Check local codes and read all instructions prior to installation.

CAUTION:

Ensure that power is off at

the electrical breaker or fuse

before beginning installation.

Ensure the Gas is off at the

shut-off before beginning

installation.

Installing the HFK-Series Cross-Flow Blower

for use with: H-Series DF/

DL & L-Series DF Gas

Fireplaces

H34-DF/DL; L38-DF
H38-DF/DL; L42-DF
H42-DF/DL; L52-DF

General Information

This blower kit is for installation on the foll owing models:

Casa H34DL / H34DF

Villa H38DL / H38DF

Estado H42DL / H42DF

L38-DF, L38-DF-I, L38-DF-A, L38-DF-F

L48-DF, L42-DF-I, L42-DF-A, L42-DF-F

L52-DF, L52-DF-I, L52-DF-A, L52-DF-F

KIT #

Contents

HFK34

2 x blowers, 1x fan cord assembly, 4 x mounting screws

HFK34H 2 x blowers, 1x fan cord assemby, 4 x mounting screws,

1x heat sensor switch

HFK42

2 x blowers, 1x fan cord assembly, 4 x mounting screws

HFK42H 2 x blowers, 1x fan cord assemby, 4 x mounting screws,

1x heat sensor switch

Before You Begin

Ensure that the power supply has been turned off at the breaker or fuse

before beginning the installation.
Shut off the gas supply at the shut-off valve, and ensure that the main

burner and pilot light have been turned off and the fireplace has been

cooled off for at least two hours be fore installation.

Installation

1a. Models H34DL, H38DL, and H42DL: Remove the lower louvres to

gain access to the control compartment. Go to Step 2.

1b. Models H-Series and L-Series: Remove the glass door to gain

access to the control compartment through the firebox.

2 Remove the accessories inside the firebox; logset, glass pebbles,

or decorative river rocks, etc

3. Carefully remove the decorative horizontal insulation panels.

Figure 2. Shut off and disconnect the gas supply.

Note: Follow the shut-down procedures for the valve installed with

your fireplace. May not be exactly as shown.

(H34DF, H38DF, and H42DF Models Only)

Gas Valve

Pan Base

Gas Inlet

Valve Bracket

NOTE: DO NOT CONTINUE UNTIL THIS STEP IS COMPLETED.

®

C

US

Figure 3. Removing the burner tray. (H34DF, H38DF, and H42DF

Models Only)

5. Remove the burner tray as shown in figure 3 for the H-DL Series

gas fireplace, and figure 3a for the L-Series DF fireplace.

4. Shut off the gas to your fireplace and shut off the control valve. See

the instruction on the placard supplied with your fireplace.

Advertising