Montigo L-Series Fireplace Surround User Manual

Tools required, Installing the surround, Surround dimensions (in inches)

Advertising
background image

XG0905 - 150204.1

Brackets to be

flush with top of

fireplace frame,

(Typical)

Align (2) attachment brackets

on center of frame verticals

(Left and Right side Typical)

Moving Brackets (2)

(Left and Right side Typical)

Mounting Holes (3) per side.

(Left and Right side Typical)

Bracket to be

Flush with

outside edge

of fireplace,

(Typical)

Installing the L-Series and P-Series Fireplace Surround

Parts Included

1) 1-Pc, Surround
2) 2-Pcs, Attachment Brackets
3) 4-Pcs, Moving Brackets
4) 1-Pkg. Hardware

Tools Required

1) Power Drill, (eight 1/8" holes)
2) #8 Hexhead Driver, (to match hardware)
3) Carpenters level (Final Step, if required)

Installing the Surround

To install the Montigo Stainless steel or Black contemporary

surround onto the L-Series or P-Series unit, follow these steps.
Step 1. Mark the location of the holes needed.
From the package of hardware locate one of the Attachment Brackets.

Hold this part in place as shown in Figure 2. With a pencil or pen mark

the (6) six holes on the face of the fireplace frame, (see Figure 2.)

Note:

Ensure the brackets align with Figure 2. Below.

Figure 2. Bracket Alignment

Step 2. Drill holes.
Before you go any farther now is the time to double check the location

of the holes, do they agree with Figure 2. If you are satisfied with the

location of the holes, use a punch to mark the holes, then using a 1/8"

drill, drill out the six holes.

M

N

P

1”

O

Surround Dimensions (in inches)

Model

M

N

O

P

P38DF/L38 DF/ST

35 5/16"

19 7/16"

49 13/16"

34 1/16"

P42DF/L42 DF/ST

39 5/8"

20 5/16"

54 1/8"

34 15/16"

P52DF/L52 DF/ST

47 3/16"

21 13/16"

65 3/16"

40 3/8"

For Use with L-Series or P-Series

L38-DF/ST

L42-DF/ST

L52-DF/ST
P38-DF

P42-DF

P52-DF

A

REVISIONS

REV.

DESCRIPTION

DATE

CHANGED BY

-

.

-

-

1:2

DWG. NO.

SHEET 1 OF 1

WEIGHT:

P38-MAN3

Finish

MATERIAL

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL 1/32"

TWO PLACE DECIMAL .015"

THREE PLACE DECIMAL .005"

ALL BENDS ARE ASSUMED

TO BE 90 UNLESS NOTED

OTHERWISE.

Revision / Date

Drawn by

DATE

NAME

P38

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

Y:\CADD\38\P38\P38

April-01-15 8:18:44 AM

SCALE

PC

Description

FACEPLATE BRACKET

MANUAL

A

Revision

04/01/2015

1

3

2

4

Figure 1. Surround Dimensions (tolerance within 1/16")