EDVRSPV Vertical Power Vent System

Part No. XG1302 - 120110

f i r e f e a t u r e

Installation

Figure 1. Typical Venting Installations.

Venting Installation

It is recommended that the External Power Vent System be used with

a gas fireplace that is equipped with HSI. When installing the vent-

ing, the installation must adhere to the Vent Installation Section in the

fireplace's Installation Operation and Maintenance Instructions, as well

as the following guidelines:

■Ensure that the planned termination location is acceptable as

shown in Appendix A.

Maximum allowed vent run is 100 feet.

Figure 2. Multi-elbow Venting Installations.

Multi-Elbow Installations
Multi-elbow installations are possible up to a maximum of six 90°

elbows.

V

Restrictor #1

Max V Max Elbows

100’ feet six 90

Elbow 1

Elbow 2

Elbow 3

Elbow 5

Elbow 4

H2

H1

V1

V2

V3

Restrictor #1

Max V1 + H1 + V2 + H2 + V3 + H3 Max Elbows

100’ feet six 90

Installing the Power Vent

Figure 4.

Step 1.
Construct a chase box around the vent penetration with exterior

dimensions of 17"x 17" x 16"MIN in height.

17”

17”

18”

Figure 3. Downward Venting Installations.

Downward Vertical Venting (HSI Models Only)
Downward venting installations are only possible with gas fireplaces

equipped with Electronic or Hot Surface Ignition (HSI).

Restrictor #1

Max V1 + H1 + D + H2 + V3 Max Elbows

100’ feet six 90

Elbow 1

Elbow 2

Elbow 3

Elbow 5

H1

V1

D = 6’ foot

MAX

V3

H2

Elbow 4