Installation, Removing and installing the insert, Removing and installing the door – Montigo ME38 ODV User Manual

Page 12

Advertising
background image

Page 1

ME38-ODV-2 Homefire

Part No. XG0123

Removing and Installing

the Insert

You may remove the insert to protect it from theft and damage dur-

ing construction.
1. Remove the two machine screws (1 left & 1 right) at the top of the

insert that attach the insert to the shell.

See Inset 1.

2. Remove the fresh air flex from the collars on the shell.

See Figure

22. Important: Be careful not to damage the fresh air flex dur-
ing removal or storage.

3. Remove the 4 machine screws that hold the venting plate to the

insert.

4. Remove the insert by tipping the top of the insert outward and lift-

ing the tabs past the slots in the bottom of the shell.

See Inset 2.

Store the screws and clamps in a safe place to ensure that they are
not lost.
To re-install the insert simply reverse the steps above.

Figure 22.

ME38-ODV-2 insert.

INSET 1

Tab

INSET 2

Mounting

Bracket

Fresh Air

Flex (4" dia.)

High temp.

silicone seal

Venting Plate

Front

Slot

Installation

Removing and Installing

the Door

Removing the Door:

Remove the trim (as described on the next page) to access the door
latches. Open the latches by pulling Part A upwards and towards
you to disengage Part B from the door. Lift Part B clear of the door.
Repeat for all three latches. Be sure to hold the door carefully so it
does not fall.

(See figure 23a.)

Once the three latches are unhinged, tilt the top of the door forward
and lift it out of the slots.

See figure 23b.

Figure 23a.

Operating the door latches.

Figure 23b.

Removing the door.

Advertising