Installation

Termination

Example 1:
For our shortest venting configuration use components A and F

(see

Figure 9a).

Figure 9a.

Typical Top Vent installation. If the 90° elbow is installed

directly on the fireplace, the height to the center of the

termination is 44".

Horizontal Venting

Figure 9b.

Typical Top Vent installation. The solid sections can be

used in various combinations to obtain the desired vent

run. The vent run must fall within the limits set by the

venting graph.

90° Elbow

MEXT Section

Heat Shield

Heat Shield

MEL-90F/F Elbow

Termination

Example 2:
A 10' section and elbow (MIHR-10) used in conjunction with 3 ft. flex
section (MFL-3) will, when extended in a five foot chase, allow for a
maximum horizontal run of twelve and one-half feet from the centre of
the fireplace to outside wall and a minimum of 7'6" when retracted in
opposite direction

(see Figure 10 and 11).

"D" flex sections and "E" solid sections may be used in conjunction
with one another to obtain different possible horizontal length instal-
lations. NOTE: Flex section with no vertical rise must not exceed

maximum horizontal length of 3 feet

(see Figure 12). Flex runs over 3

feet must fall within the limits set by the venting graph, and must have
a minimum vertical rise of 3" per foot of flex.

Top Vent

Figure 10.

Extended Installation using a combination of solid and

flex venting. Use the vent graph to determine your allow-

able run, then select appropriate components.

Figure 11.

Retracted Installation using a combination of solid and

flex venting. Use the vent graph to determine your allow-

able run, then select appropriate components.

Figure 12.

Horizontal flex installation with no vertical rise.

Hearth

Termination

Exterior

Wall

3' max.

Flex Section

Hearth

Flex Section

Termination

Exterior

Wall

Solid Sections

Heat
Shield

Heat
Shield

Hearth

Flex Section

Solid Sections

Termination

Exterior
Wall

Heat
Shield

150" max.

30" max.