MultiDyne DVI-6000 Series User Manual

Page 9

Advertising
background image

Instruction Manual, DVI-6000 FTX/FRX

9


As in the FTX, there is also an USB connector and activity LED on the front panel for GUI

mode.

FRX FRONT PANEL SWITCH FUNCTIONS: Refer to Fig 3. As in the FTX, there are 7 switches
labeled A thru G. Their functions are as follows:


Switch
A is used when the optional cable input is fitted. If both cable and fiber inputs are

active simultaneously, it is used to assign priority between the two. It chooses between the optical
input (up) and cable input (down). When only one type of input is present, it chooses that input
regardless of the switch position.


Switch
B this switch is used to select the 3G SMPTE option when down and the 3.75G

transport options when up. If the optional cable connection is used, 3G mode should be used.


Swtich
C is used to select which of the 2 DVI outputs will be used for EDID polling. Up is

OUT1, down is OUT2. This switch is not used if BDD is not fitted.


Swtich
D, when down, enables polling of the chosen monitor for EDID. Caution: Enabling

this mode will overwrite any contents of the EDID PROM in the FTX. This switch is not used if
BDD is not fitted.


Switches
E thru G are for data protocol setting and have the same functionality as in the

FTX. Switch G, which enables 100 ohm termination across the data inputs, is only valid when
BDD is fitted.

POWER REQUIREMENTS


The DVI-6000-FTX requires 9~24VDC @ TBDA and the DVI-6000-FRX requires 9~24VDC

@ TBDA. These are provided by 12 VDC output, 100-240 VAC input power supply modules,
included.
















Advertising