Wiring diagram, Terminal strip dkw 976 – REMKO SLV11-88-2 User Manual

Page 10

Advertising
background image

10

Wiring Diagram

Control relay DKW 976 for the model sizes SLV 11 to SL 44

L1

N

T1

T2

S3

B4

Control line to

warm air generator

L1

N

T1

T2

S3

B4

7-pin connector

in accordance
with DIN 4791

Caution !

4-pin plug is only used

internally and has to be

plugged in during

operation

B5

T6

T7

T8

B5

T6

T7

T8

MV2 MV1

ZT

FW

M

Terminal strip DKW 972

Terminal strip Conectron LKS 130-2 adjustment motor

6 A

8

4 1 2 3 8 5 7 9

8

4 8

7

3

1 2

Control relay DKW 972 model sizes SL 55/2 and SL 66/2

L1 N

T1

T2

S3

B4

Terminal strip DKW 976

FW

N

C1

WS

Z M

MV1

MV2 SA

ÖV

FT

1 2

3 4 5 6 7 8 9

B

1)

1)

1) Note: Burner of the SL 44 model size without nozzle connection rod preheater. Preinstalled bridge from terminal 4 to 6.

We reserve the right to make changes to dimensions and design in the interest of technical progress.

Advertising