6

Technical Data

Wiring Diagram

4

L1

PE

6

5

4

3

N

2

1

6

5

1A

2A

3A

4B

5B

6B

11

14

31

34

A1

A2

HR

KL

TB

M

HW

S

TH

PE

N

L1

230/1~ 50Hz

NK

ϑ

Series

TX 3000

Nominal heat output

kW

3,0

Air output

m³/h

300

Electrical connection

V

230/1~, N,

PE

Frequency

Hz

50

Rated current max.

A

13,1

Power consumption max.

kW

3,05

Fuse protection (required)

A (inert)

16

Sound pressure level L

pA

1m

1)

dB (A)

46

Dimensions Length mm

400

Width

mm

200

Height

mm

340

Weight

kg

8,0

1) noise measuring DIN 45635 - 01 - KL 3

Legend

HR = contactor

HW = heating element

KL = terminal

strip

M = fanmotor

NK = recool thermostat

S = operating switch

TB = temperature

limiter

TH = room thermostat

Troubleshooting

Unit (fan) does not start:

1. Check main fuse

2. Check connecting cable with plug

3. Check operating switch

4. Check slight drifting of fan (motor)

Unit does not heat

1. Check operating switch

2. Check function of the temperature limiter

3. Check room thermostat

4. Check room thermostat-operation: thermostat must

be set higher than the room temperature

Should the unit still not be working despite these checks,
please contact an authorised service centre.

Prior to starting any work make sure to pull the
mains plug out of the mains socket!

Setting and maintenance is to be carried out
only by authorised experts!