Commissioning wizard

The commissioning wizard which starts when the

controller is activated is intended for programming

the controller for use on the existing system. When

the individual parameters are activated or deacti-

vated, corresponding parameter sets are uploaded

automatically, although they are not visible. After

commissioning has been fully completed, the

default set of parameters is enabled. During the

first heating period the thermal characteristics of

the system should be observed, and the parame-

ters optimised as necessary. The lower the

selected water temperatures, the more efficient

operation of the heat pump will be.

You can find simplified commissioning exam-

ples

Ä Chapter 4.3 ‘Template hydraulic dia-

grams with installation parameters’

on page 49

Should you require the installation wizard again at

a later point in time (e.g. if you are expanding the

existing system), then you can also call it up man-

ually at any time from the main menu.

Proceed with installation as follows:

Fig. 28: Setting parameters

Fig. 29: Confirm the entry with "OK", then jump to

the next setting with "Next"

Assigning the unique unit identifier

Here you can address up to 3 Smart Control units.

Select the unit identifier with the rotary knob and

confirm the entry with "OK". The unit ID number

appears before a red, flashing field in the top right

of the display.

1

Fig. 30: Assigning the unit identifier

Menu item

Parameter

Factory setting

Con-

trol panel 1

address

Control panel 1

Control panel 1

Control panel 2

Control panel 3

Press "Next".