Installation

For The Electrician

This unit must be on a separate 115 volt AC 60
cycle single phase power supply. The maximum
fuse size for this circuit is listed on the nameplate,
and per the nameplate use fuses, or HACR circuit
breakers.

To make the electrical connections:

1. Remove the right top panel.

2. Remove the junction box cover.

3. Make the electrical connections to the wires in
the junction box. A ground screw is provided in the
junction box.

Follow All Local Codes - This Unit Must Be
Grounded
. Usually a licensed electrician will be
required to connect the electrical service.

Hand Disconnect Switch

Junction Box

SLC300

November 1994

Page 9