MGP-FA752-3A

High discharge pressure.

Cannot be adjusted lower.

Adjustable pressure valve not func-

tioning.

Air Leaks

Hose fitting loose.

Prolonged excessive use of air.

Decrease the amount of air usage. Your compres-

sor is not large enough for the air requirement.

Tighten fitting.

Compressor is not delivering

enough air.

Replace the hose.

Hole in hose.

Air leaks.

Tighten fittings.

1. Check fuse box for blown fuse and replace as

necesssary. Reset circuit breaker. Do not

use a fuse or circuit breaker with higher rating

than that specified for your particular branch

circuit.

2. Check for proper fuse. You should be using a

Quick Acting fuse.

3. Check for low voltage problem.

4. Check the extension cord.

5. Disconnect the other electrical appliances

from circuit or operate the compressor on its

own branch circuit.

Fuse blown, circuit breaker tripped.

Motor will not run.

Extension cord is wrong length or

gauge.

Check the extension cord.

Loose electrical connections.

Check wiring connection inside terminal box

Faulty motor.

Have checked at a local Service Center.

VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES ARE EXPOSED
WHEN REPAIRING THE COMPRESSOR. PERSONAL INJURY CAN OCCUR. UNPLUG THE
COMPRESSOR BEFORE ATTEMPTING ANY REPAIRS.

RISK OF BURSTING. DO NOT OPERATE
THE COMPRESSOR IF THIS PROBLEM
EXISTS. ADJUSTABLE PRESSURE VALVE
MUST BE REPLACED.