GLD140 SERIES INSTALLATION INSTRUCTIONS

OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some applications where an
overvoltage condition could result in a hazard as defined in applicable safety standards, redundant or additional overvoltage
protection may be required. Consult factory for details.

CAUTION: When performing Dielectric Strength Tests, catastrophic failure of the unit may result if a Dielectric Strength
test voltage greater than 1800 V ac is applied between primary and secondary circuits. The components providing isolation
from primary to secondary cannot be tested while installed in the power supply without overstressing basic (primary to
ground) insulation. All isolating components are individually 100 % tested at 4800 V ac prior to installation.

TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components.

FUSING: Fuses for both Line and Neutral are provided in the power supply. A blown fuse is an indication of catastrophic
failure of circuit component(s). Repair must be performed by Condor authorized personnel. Refer to fuse markings for type
and rating.

WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring traces and heatsinks.

CONNECTIONS

J1 AC Input

J2 Signal Out

J3

DC Output

J5 FAN

1 Earth

1 + Sense

9, 10, 19, 20

V1

1

Fan Return

3 AC Neutral

2 - Sense

5, 14, 15

V2

2

+ Fan

5 AC Line

3 Power Fail

4

V2 Sense

4 Power Good

1

V3

MATING CONNECTORS

5 Common

11

V3 Return

J1: Molex P/N 39-01-4051 (Housing)

6 Inhibit

2

V4

Molex P/N 39-00-0038 (Pins)

3, 6-8, 12, 13, 16-18 Common

J2 and FAN: Amp MTA-100 Receptacle

J3: Molex P/N 39-01-2200 (Housing)

Molex P/N 39-00-0038 (Pins)

CAUTION: Do not exceed 7 A per pin on connector J3

Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
and EN/IEC safety standards.

41-34338-0001 Rev. G 11/30/05