SL Power Electronics GLM110 User Manual

Installation instructions glm110 series

Advertising
background image

CONDOR DC POWER SUPPLIES INC.
2311 STATHAM PKWY
OXNARD, CA 93033 + 805-486-4565
Internet: www.condorpower.com

MODEL NUMBERS: GLM110-X, where X = 12, 15, 24, 212, 215, or 524. May be followed by suffix
–L to indicate optional chassis or –LC to indicate chassis/cover and/or suffix –XXX where XXX may be
any number from 001 thru 999 to indicate value added configurations that have no impact on safety
and/or suffix G to indicate compliance to RoHS.

RATINGS:

Input: 100-240 V ac, 2.9 A, 50/60 Hz
Output:

0 CFM

0 CFM

26 CFM

60 Watts Max 75 Watts Max

110 Watts Max

MODEL

Output Volts

With Cover

Without Cover

With or without cover

GLM110-12

#1

12

5.0 A

6.3 A

9.1 A

GLM110-15

#1

15

4.0 A

5.0 A

7.3 A

GLM110-24

#1

24

2.5 A

3.2 A

4.6 A

GLM110-212

#1

+12

5.0 A

6.3 A

9.1 A

#2

-12

2.5 A

2.5 A

3.0 A

GLM110-215

#1

+15

4.0 A

5.0 A

7.3 A

#2

−15

2.5 A

2.5 A

3.0 A

GLM110-524

#1

+24

2.5 A

3.2 A

4.6 A

#2

+5

1.5 A

1.5 A

2.0 A

Notes: 1. Maximum ambient temperature for rated output current is 50 °C.

2. Maximum Operating Relative Humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before

application of power.

CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of
UL 60601-1, CSA 22.2 No. 601.1, and EN 60601-1.


CLASSIFICATION: (5.1) Protection against electric shock = Class I

(In accordance with sub-

(5.2) Degree of protection against electric shock = Signal output or intermediate

clause 5 of IEC 60601-1)

(5.3) Protection against harmful ingress of water = Ordinary (no protection)

(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic
mixture with air, oxygen, or nitrous oxide. This evaluation is to be made on the
end equipment by the OEM.

(5.6) Mode of operation = Continuous

SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole
responsibility that all models listed above are in conformity with the applicable
requirements of EN 60950-1 following the provisions of the Low Voltage Directive

73/23/EEC.

GROUNDING: Protection Class I requires that the ground terminal be bonded to Protective Earth in the
end application. Using this terminal for the primary system earthing terminal is not recommended.

OUTPUTS: Output common or return should be connected to Protective Earth in the end application.
The output is intended for Protectively Earthed Signal Output and Intermediate Circuits only. The
output is not acceptable for patient connection without additional isolation. The DC output is SELV
under normal and single fault conditions.

41-34727-0001 Rev. D 10/21/05

Page 1 of 2