OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some
applications where an overvoltage condition could result in a hazard as defined in applicable safety
standards, redundant or additional overvoltage protection may be required. Consult factory for details.

CAUTION: When performing Dielectric Strength Tests, catastrophic failure of the unit may result if a
Dielectric Strength test voltage greater than 1800 V ac is applied between primary and secondary
circuits. The components providing isolation from primary to secondary cannot be tested while installed
in the power supply without overstressing basic (primary to ground) insulation. All isolating
components are individually 100 % tested at 4800 V ac prior to installation.

ISOLATION: The creepage distance between primary and ground is 4 mm minimum; between primary
and secondary circuits is 8 mm minimum. Secondary to ground creepage is not defined or controlled.
The required creepage and clearance distances from primary circuits to ground and secondary circuits
must be maintained after installation to preserve the intended safety.

TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in
the applicable safety standards, must not be exceeded after installation to preserve the intended safety.
The output power, ambient air temperature and the availability, amount, direction and/or restriction of
airflow influence the temperatures of these components.

OVERCURRENT PROTECTION: The internal fuse is located in the phase lead only. EN 60601-1
requires that both supply leads (phase and neutral) be protected against overcurrent. Complete
overcurrent protection must be provided in the host equipment. Fuse ratings must not exceed that
specified for the internal fuse, must meet the requirements of EN
60601-1, and be acceptable for the country in which the host
equipment is to be installed.

WARNING! RISK OF FIRE! A blown internal fuse is an
indication of catastrophic failure of circuit component(s). Refer to
fuse marking on the supply for rating. Repair must be performed
by Condor authorized personnel.

WARNING! SHOCK HAZARD! Dangerous voltages are present
on some components, printed wiring traces and heatsinks.

C O N N E C T I O N S

Single Output Models

Multi-Output Models

J1 Pin

AC Input

J2 Pin

DC Output

J2 Pin

DC Output

J2 Pin

DC Output

J2 Pin

DC Output

1

Ground

1

+ Output

8

Return

1

Output #1

8

Common

3

Neutral

2

+ Output

9

Return

2

Output #1

9

Common

5

Line

3

+ Output

10

Power Fail

3

Output #1

10

Power Fail

4

+ Output

11

N/C

4

Output #1

11

N/C

5

Return

12

N/C

5

Common

12

Output #2 (-)

6

Return

13

N/C

6

Common

13

Output #2 (+)

7

Return

7

Common

MATING CONNECTORS

CAUTION:

J1 Amp/Tyco Housing 640250-5

Contact 640706-1

Do not exceed 5 A per contact.

J2 Amp/Tyco Housing 1-640250-3

Contact 640706-1

Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
and EN/IEC safety standards.