RATINGS:
Input: GPHP600: 100-240 V ac, 8.5 A, 50/60 Hz

GPHP700: 100-240 V ac, 9.5 A, 50/60 Hz

Outputs:

Output #1

Total

Model #

V

A

Watts

GPHP600-24-YYY

24

25/27 pk

600

GPHP600-28-YYY

28

21.5/23.5 pk

600

GPHP600-36-YYY

36

17/19 pk

600

GPHP700-48-YYY

48

14.6/15.6 pk

700

NOTES: 1. Maximum ambient temperature for rated output power is 50°C utilizing two integral 27 CFM fans.

2. Maximum Operating Relative Humidity 96%, no condensation.

3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before

application of power.

4. Peak current, 60 Sec with a 10% duty cycle
5. YYY indicates front cover colors and mounting options not related to safety.

SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950 following the provisions
of the Low Voltage Directive 73/23/EEC. All models are certified to be in compliance with the applicable
requirements of EN/IEC/UL 60950-1 1

st

Ed., CAN/CSA 22.2 No. 60950-1:03 (Level 5). They are certified

for Pollution Degree 2 environment and Class I TN-S power systems. All DC outputs are SELV under

normal and single fault conditions.

TEMPERATURES: The maximum operating temperatures of components used in this supply must not be exceeded after
installation. The orientation of the supply, output power, ambient temperature and the availability, amount, direction and/or
restriction of natural airflow influences the temperatures of these components.

THERMAL PROTECTION: The unit has a thermal protection circuit that will shut down the unit if an overtemperature
condition is encountered. Recovery is automatic.

GROUNDING: At least one of the Functional Earth (Ground) pins (Z28, D26) must be bonded to Protective Earth in the
end application. The pins have been tested for use as a protective earth. The end application should be evaluated to ensure it
meets the Protective Earthing requirement.

OVERVOLTAGE PROTECTION: The unit has overvoltage protection that is factory set to trip at a maximum of 136% of
the nominal output voltage. The unit must be cycled off, then on to reset.

HOT SWAP: The unit has been evaluated and found acceptable for HOT SWAP applications. The ground pin makes before
and breaks after the AC input pins.

CURRENT SHARING: Built-in OR-ing diodes on all outputs along with the HOT SWAP capability allow multiple units to
share the same rack configuration and share the load.

NOTE: Adjacent units must be set within 0.2% of each other for proper current share.

VOLTAGE ADJUSTMENT: Factory set to specified voltage. User accessible pot allows adjustment over a range of ±5%
of nominal voltage. The potentiometer is located on the A2 PWB located behind and above J1.

SPACINGS: The required creepage and clearance distances from primary circuits to ground and secondary circuits must be
maintained after installation to preserve the intended safety.