background image

Code No. 0816488

Rev. 0 (08/08)

INSTALLATION INSTRUCTIONS FOR

FOOT PEDAL ACTIVATED WATER CLOSET AND URINAL FLUSHOMETERS

LIMITED WARRANTY

Sloan Valve Company warrants its Sloan Flushometers to be made of first class materials, free from defects of material or workmanship under normal use and to perform the
service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes)
from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan
Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental
costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale.

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE

FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

PRIOR TO INSTALLATION

Before installing the Sloan Flushometer, be sure the items listed below are
installed. Also, refer to the rough-in diagrams on Page 2.
• Closet/urinal fixture
• Drain line
• Water supply line
• Drill holes in wall for foot pedal actuator and water inlet to fixture
Due to code restrictions and installation practices, the Crown Naval 313
INT’L is for International use only.

Important:

INSTALL ALL PLUMBING IN ACCORDANCE WITH APPLICABLE CODES

AND REGULATIONS.

• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE

VOLUME OF WATER FOR EACH FIXTURE.

• FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.

Most Low Consumption water closets (1.6 gallon/6.0 liter) require a
minimum flowing pressure of 25 psi (172 kPa).

The Sloan Flushometer is designed to operate with 15 to 100 psi (104 to
689 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE
VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult
fixture manufacturer for minimum pressure requirements.
Most Low Consumption water closets (1.6 gpf/6.0 Lpf) require a minimum
flowing pressure of 25 psi (172 kPa).
Protect the Chrome or Special finish of this Flushometer — DO NOT USE
TOOTHED TOOLS TO INSTALL OR SERVICE THE VALVE. Also, see "Care and
Cleaning" section of this manual.
IMPORTANT: EXCEPT FOR CONTROL STOP INLET, DO NOT USE PIPE
SEALANT OR PLUMBING GREASE ON ANY VALVE COMPONENT OR
COUPLING!

TOOLS REQUIRED FOR INSTALLATION

• Straight blade screwdriver for stop adjustment (exposed models only)
• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed

spud wrench

• Hole saw for foot pedal actuator and water inlet to fixture
• 1/16” hex wrench for supply flange (exposed models only)

Royal 310

Exposed Model Shown

Royal, Regal, and

Crown Naval

Models 310, 312, 313, 313 INT’L,

318, 320, 323 and 343

Exposed and Concealed

Foot Pedal Activated

Closet and Urinal

Flushometer Valves

Royal 313

Concealed Model Shown

Crown Naval 313 INT’L

Concealed Model Shown

Made in the U.S.A.

Advertising