Adjust control stop and install stop cap – Sloan 310 Foot Pedal Flushometer User Manual

Page 5

Advertising
background image

5

7

8

Flush Out Supply Line

Connect Foot Pedal Actuator
Assembly to Flushometer

A

Make sure Control Stop is
CLOSED and remove
Flushometer Outer Cover.

C

Reinstall Outside and
Inside Cover wrench tight.
Open Control Stop to
flush supply line. Close
Control Stop and remove
Outside and Inside Cover.

B

Remove Inside Cover and lift out
Inside Parts Assembly.

D

Reinstall Inside Parts
Assembly, Inside Cover and
Outside Cover wrench tight.

CONTROL

STOP CAP

D

Install Control Stop Cap
onto Control Stop.

B

Activate
Flushometer.

A

Open Control Stop COUNTERCLOCKWISE one FULL turn from
closed position.

C

Adjust Control Stop after each flush until the rate of flow delivered
properly cleanses the fixture.

TURN COUNTER-

CLOCKWISE TO OPEN

TURN CLOCKWISE

TO CLOSE

ACTUATOR

SHAFT END

COUPLING

MOUNTING NUT

WALL

(FIXTURE SIDE)

ACTUATOR
ASSEMBLY

6

Mount Foot Pedal Actuator
Assembly to Wall
(Concealed Models)

A

Remove Actuator Shaft End, Coupling and Mounting Nut from
Actuator Assembly.

B

Insert Actuator Shaft through the 1½” (38 mm) wall opening from
fixture side of wall.

C

Install Mounting Nut, Coupling and Actuator Shaft End to Actuator
Assembly. Hand tighten Mounting Nut to wall.

D

Securely tighten Actuator Shaft End to Actuator Assembly.

9

Adjust Control Stop and Install
Stop Cap

COUPLING

NUT

A

Install Gasket between the Actuator Assembly and opening in
Flushometer.

B

Install Coupling Nut onto
Flushometer hand tight.

C

Tighten ALL
couplings securely.

A-31-P GASKET

FLUSHOMETER

OPENING

ACTUATOR
ASSEMBLY

Important Note: Use a Sloan A-50 “Super-Wrench™”, A-109 Plier Wrench
or smooth jawed spud wrench to secure all couplings. This will eliminate
damage to chrome or special finish that normally occurs when slip-joint
pliers, pipe wrenches or other “toothed” tools are used.

Sloan Flushometers are engineered for quiet operation. Excessive water

flow creates noise, while too little water flow may not satisfy the needs

of the fixture. Proper adjustment is made when plumbing fixture is

cleansed after each flush without splashing water out from the lip

AND a quiet flushing cycle is achieved.

Never open Control Stop to where the flow from the valve exceeds the

flow capability of the fixture. In the event of a valve failure, the fixture

must be able to accommodate a continuous flow from the valve.

!!! IMPORTANT !!!

D

Tighten Actuator Mounting Nut securely against wall (exposed
model).

EXPOSED

CONCEALED

COUPLING

NUT

A-31-P GASKET

FLUSHOMETER

OPENING

ACTUATOR
ASSEMBLY