WITH THE EXCEPTION OF THE CONTROL STOP INLET,

DO NOT USE PIPE THREAD SEALANT OR PLUMBING

GREASE ON VALVE COMPONENTS OR COUPLINGS.

PROTECT THE CHROME OR SPECIAL FINISH OF SLOAN’S

FLUSHOMETERS. DO NOT USE TOOTHED TOOLS TO INSTALL OR

SERVICE VALVES. USE A SLOAN A-50 SUPER WRENCH™, SLOAN

A-109 PLIER WRENCH OR SMOOTH JAWED SPUD WRENCH TO

SECURE COUPLINGS. SEE “CARE AND CLEANING” SECTION FOR

MORE DETAILS.

NEVER OPEN THE CONTROL STOP TO WHERE THE FLOW FROM

THE VALVE EXCEEDS THE FLOW CAPABILITY OF THE FIXTURE. IN

THE EVENT OF A VALVE FAILURE, THE FIXTURE MUST BE ABLE TO

ACCOMMODATE A CONTINUOUS FLOW FROM THE VALVE.

THIS PRODUCT CONTAINS MECHANICAL AND THAT ARE SUBJECT

TO NORMAL WEAR. THESE COMPONENTS SHOULD BE CHECKED ON

A REGULAR BASIS AND REPLACED AS NEEDED TO MAINTAIN THE

VALVE’S PERFORMANCE.

!!! IMPORTANT !!!

!!! IMPORTANT !!!

!!! IMPORTANT !!!

!!! IMPORTANT !!!

A

Slide the spud coupling, nylon slip gasket, rubber gasket and

spud flange over the vacuum breaker tube.

VACUUM

BREAKER

ELBOW

FLUSH

CONNECTION

RUBBER

GASKET

NYLON

SLIP

GASKET

B

Insert tube into fixture spud. Hand tighten spud coupling

onto fixture spud.

VACUUM

BREAKER

TUBE

SPUD

COUPLING

SPUD

COUPLING

NYLON

SLIP

GASKET

RUBBER

GASKET

SPUD

FLANGE

SPUD

FLANGE

MODELS

920, 921 & 922

MODELS

910, 913, 915,

916 & 917

MODEL

980

MODEL

986

VACUUM

BREAKER

TUBE

SPUD

COUPLING

NYLON

SLIP

GASKET

RUBBER

GASKET

SPUD

FLANGE

A

Measure from finished wall to C/L of Fixture Spud. Cut pipe 1¼” (32

mm) shorter than this measurement. Chamfer O.D. and I.D. of water

supply pipe.

WATER SUPPLY PIPE

FINISHED WALL

1-1/4”

(32 mm)

C/L OF

FIXTURE

SPUD

SWEAT

SOLDER

ADAPTER

B

Slide Threaded Adapter fully onto pipe.

C

Sweat solder the Adapter to pipe.

BAK-CHEK

®

CONTROL STOP

COVER TUBE ‡

IRON PIPE NIPPLE OR

COPPER PIPE WITH SWEAT

SOLDER ADAPTER

SET SCREW

SUPPLY

FLANGE ‡

WATER

SUPPLY PIPE

SWEAT SOLDER

ADAPTER

COVER TUBE

WALL

FLANGE

SET SCREW

A

Measure from finished wall

to first thread of adapter

or threaded supply pipe

(dimension “X”). Cut cover tube

to this length.

B

Slide cover tube over pipe.

Slide wall flange over cover

tube until against wall.

Install the Sloan Bak-Chek

®

control stop to the water supply

line with the outlet positioned

as required.

C

Tighten Set Screw with a 1/16”

hex wrench. DO NOT install vandal

resistant stop cap at this time.

D

‡ Cover Tube

and Supply

Flange with

Set Screw is

supplied with

Royal valves;

available in

“YBYC” Sweat

Kit for Regal

valves.

1 - INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD)

2 - INSTALL COVER TUBE, WALL FLANGE, AND CONTROL STOP TO SUPPLY PIPE

3 - INSTALL VACUUM BREAKER FLUSH CONNECTION

When further assistance is required, please consult your local Sloan