Super Systems 13036 User Manual

Page 2

Advertising
background image

SsiManual 4515 D

13036 Probe Conditioning System

Table Of Contents

Introduction . . . . . . . . . . . . . p. 1
Specifications . . . . . . . . . . . . p. 1
Description . . . . . . . . . . . . . . p. 1
Installation . . . . . . . . . . . . . . p. 2
Operation . . . . . . . . . . . . . . . p. 2
Wiring Diagram. . . . . . . . . . . p. 3
Revision History . . . . . . . . . . p. 4

INTRODUCTION

Thank you for selecting

SSi

P/N 13036 for your generator probe maintenance application.

You lubricate critical machine parts on a regular basis if you want them to last. Your zirconia
carbon sensor also requires regular maintenance. Buildup of carbon in the space between the
zirconia sensing element and the sheath, as well as at the sensing point, will eventually adversely
affect the proper operation of the probe. If carbon (soot) is allowed to accumulate to the extent
that the atmosphere cannot penetrate to the sensing surface, control is impossible. The 13036 is
designed to prevent that from happening. By periodically initiating a procedure from the SSI
SlikGen or AC20 controls to remove the accumulated carbon, the carbon sensor is maintained in
a clean operating condition. The 13036 is intended for use with generator-dew point sampling
(reheat) systems only. This system can perform very well with low burnoff flow rates since the
sample flow is stopped and displaced by burnoff air.

SPECIFICATIONS

Reference air flow- 2scfh max
Burnoff air flow- 10scfh max.
Burnoff time- 1 to 10 minutes

Dimensions- 10" x 10" x 6"
Weight- 17.8 lbs
Actuation- Cycle times- 5 to 50

hours.

DESCRIPTION

The 13036 Generator Probe Conditioning Box is designed for use with generator sampling or
reheat systems. While the SSI 13003 system is equipped with internal timers to conduct the
burnoff routine, the 13036 is actuated by SSI AC20 or other controls. Existing burnoff systems
that were designed to work with a programmable controller cannot provide adequate air for
burnoff because they simply switch the output of small reference air pumps to the burnoff fitting
without regard to adequate flow. Fig. 1 shows the piping and wiring diagram of the SSI B.O.
Box.

PROBE CONDITIONING SYSTEM MANUAL

Page 1

Advertising