INTRODUCTION

Thank you for selecting

SSi

P/N 13039 for your batch furnace, probe maintenance application.

You lubricate critical machine parts on a regular basis if you want them to last. Your zirconia
carbon sensor also requires regular maintenance. Buildup of carbon in the space between the
zirconia sensing element and the sheath, as well as at the sensing point, will eventually adversely
affect the proper operation of the probe. If carbon (soot) is allowed to accumulate to the extent
that atmosphere cannot penetrate to the sensing surface, control is impossible. The 13039 is
designed to prevent that from happening by accepting signals from the AC20 controller to
conduct a procedure to remove the carbon. It is intended for use with batch and continuous
furnaces. (See P/N 13036 for generators.)

SPECIFICATIONS

Reference air flow- 2 scfh max
Burnoff air flow- 10scfh max
Actuation- N.C. inner door switch.

Dimensions- 10" x 10" x 6"
Weight- 17.4 lbs

DESCRIPTION

The 13039 probe conditioning box is designed for use with batch and continuous furnaces.
Existing burnoff systems that are designed to work with a programmable controller cannot be
used as "stand alone" systems without significant modification. Further, most cannot provide
adequate air for burnoff because they simply switch the output of low flow reference air pumps
to the burnoff fitting without regard to adequate flow. Fig. 1 shows the piping and wiring
diagram of the 13039 PC Box