Clearances, Examples – Dometic RM660 User Manual

Page 8

Advertising
background image

CLEARANCES

Minimum clearances in inches to combustible materials are

G: Top 0
K: Side 0
L: Bottom 0

M: Rear 1

Clearance M between the rearmost part of the refngerator and
the wall behind the refrigerator
Clearance N on top of the condenser is related to the
minimum’ventilation height
See Fig 11 and examples below

Fig. 11

Refrigerator Overall Installation

Recess Distance between

model dimensions dimensions

dimensions

top of condenser to
top of refrigerator

Height Width

Depth Height

Width Depth Height Width

Depth

A B C h

W

d H W D e

RM360 30 3/8 21 11/16 22 1/16 29

20 1/4 20 3/16 29 3/4 20 1/2

21 3/16 1 1/4

RM460 32

23 24 11/16 32 1/8 21 9/16 22 3/4 32 5/16 21 13/16 23 3/4 1 1/4

RM660 40 13/16 23 24 11/16 40 21 9/16 22 3/4 40

21 13/16 23

1 1/4

RM760 52 23 24 11/16 51 3/16 21 9/16 22 3/4 51 3/8 21 13/16 23 3/4 1/8

RM1300 57 15/16 24 15/16 24 11/16 57

23 7/16 22 3/4 57 1/2 23 13/16 23 3/4 1/8

EXAMPLES

The clearance N for the RM360 model

IS

derived at in the

following way

Installation with upper and lower side vents
N=Minimum ventilation height 37 minus installation height

29 9/1 6 plus distance between condenser top and refrige-

rator top 1 1/4
N=37-29 9/16+1 1/4=8 11/16

Installation with roof vent and lower side vent

N=Minimum ventilation height 31 minus installation height

29 9/1 6 plus distance between condenser top and refrigerat-
or top 1 1/4 plus distance between roof surface and roof
vent cap 5 1/4
N=31-29 9/16+1 1/4+5 1/4=7 15/16