7 TECHNICAL

CHARACTERISTICS

Accuracy (VDE / VDI 3513):

± 2,5% of full scale value.

On

order:

±

1,6%

of

full

scale.

Range ability:

10:1

Scale length: ~100

mm.

Scales:

Direct in l/h etc. or in %.

Mounting::

Vertical or horizontal.

Pipe fittings:

DIN flanges (others on order).

Materials:

Metering tube:

EN 1.4404 (AISI-316L), PVC, PTFE, PP (others on
order).

Spring

EN 1.4319 (AISI-302)

Indicator housing

Aluminium, PP, EN 1.4404 (AISI-316L)

Working pressure:
Depending on the metering tube material

- EN 1.4404

PN40 DN15 ... DN50

PN16

DN65

...

DN80

- PVC / PTFE / PP

PN16 DN15 ... DN50

PN10

DN65

...

DN80

- EN 1.4404+PVC / PTFE / PP PN40 DN15 ... DN40

PN16

DN50

...

DN80

PN10

DN80

Working temperature:

Standard:

- EN 1.4404:

-50ºC ... +200ºC

- PVC:

0ºC ... + 50ºC

- PTFE:

-20ºC ... +150ºC

- PP:

-20ºC ... + 85ºC

With thermal separator:

- EN 1.4404:

-200ºC ... +400ºC

Mounting length:

250

mm

Ingress protection:

IP65

Conforms with the Pressure Equipment Directive 97/23/CE.

This equipment is considered as being a pressure accessory and NOT a safety accessory
as defined in the 97/23/EC directive, Article 1, paragraph 2.1.3.

7.1

Optional limit switches:

SC-AMM:

Micro-switch mounted in the indicator housing.

• Maximum current: 3A.

• Maximum voltage: 250 VAC.

SC-AMD:

DIN 19234 (NAMUR) vane operated inductive detector, mounted in the
indicator housing.

• Nominal voltage: 8.2 VDC

• ATEX certificate Exia IIC T4 or T6

Advertising