use compact (55 watt)
fluorescent lamps.

Osram Studioline

®

Lamps

(Manufacturer rated lamp life 8,000 hrs)
Designed for use in video & digital imaging
for higher output.

Tungsten

CRI

°K

FLS-55TU Studioline 55w/3200

85 3200

Daylight

CRI

°K

FLS-55DA Studioline 55w/5600

85 5600

GE Cinema-Plus

®

Lamps

(Manufacturer rated lamp life 8,000 hrs)
Better lighting for film (still or motion picture)
due to better color rendering with film
emulsions. May require “minus green”
filtration gel (1/8).

Tungsten

CRI

°K

FLC-55TU GEF55BX/CINPLUS32 90+ 3200

Daylight

CRI

°K

FLC-55DA GEF55BX/CINPLUS55 90+ 5500

Lamp Changes

To change a lamp, remove any front
accessories, if attached. Remove the
screws attaching the metal endplates A.

*Note that the light-tube sockets are installed
on alternating ends of the fixture. To remove a
tube, gently grasp it by its glass end and
swing it slightly out from the fixture while
pulling it carefully from the socket.

Note: Take care when lifting lamps away from
the spring loaded retaining clips in the center
of the tube end of the lamp.

Replace lamps in same way, opposite order.
Be very careful as lamp-tubes are fragile and
can easily shatter. Read lamp mfr’s Warnings.

Lamps & Lamp Changes

e-studio fixtures come with a
user-replaceable mini fuse which
is installed in a small holder on the
same plate as the exterior AC power
socket. Access the fuse by removing
the cap with a small flathead
screwdriver. Swap fuse if necessary
and replace holder.

See the Technical Specs chart below to find
the correct fuse rating for the e-studio model
& voltage that you are using.

Fuse Change

Technical Specs

Repairs & Info

The following Accessories
can be attached to the
front of the fixture,
by opening the rotating
lock A sliding the
accessory into the top
& bottom slots on the
fixture face, and closing
the rotating lock.
Only one accessory
can be used at a time.

Intensifier

The mirrored Intensifier, when attached, can
almost double the light output of the fixture.
Assemble before attaching to light by placing
2 adjoining sides together at a right angle
& tightening screws. When both halves are
assembled, join them together and tighten
screws. Slide assembled intensifier into front
slot on fixture, close safety locks.

Note: Intensifier has grooved slot on front for
attachment of Honeycomb Grid to trim light.
Choose correct size of Honeycomb Grid.

Barndoors

For trimming spill of the light, slide
Barndoor assembly into slot on fixture,
and secure locks. Open doors and adjust
for proper trimming of spill. Do not operate
unit with Barndoors closed.

Egg Crates

for controlling spill. Slide the Egg Crate into
the front accessory slot. Less control than
Honeycomb Grid, with less output loss.

Honeycomb Grid

Each fixture has 2 options for using
honeycomb grids to control the spill of
the light, either placing the grid on the front
of the fixture, or attaching it to the front
of the Intensifier. It is not possible to use
the “front of fixture” grid with the Intensifier.
The grids are available in black with 20, 30,
or 40 degree dispersion. Honeycomb Grids
cause some loss of light output (see chart).

Note: e-studio fixtures have installed
Gel Clips. For using colored or diffusion gels
in front of the fixture. Attach pre-cut gel
material to the 4 spring clips on the corners
of the front reflector plate

Repairs, problems, suggestions
and requests for brochures/catalogs,
instructions and parts lists can
be handled through your Authorized
Lowel Dealer/Distributor or directly
through Lowel. Electrical repairs
should be made only by Lowel
or by a qualified electrician.

Amperage: See charts, for models operating at 120VAC or 240 VAC 50/60 Hz.
Fuse Ratings/Classement des fusibles: 50/60Hz
Power Factor: >.99

Lowel-Light
Manufacturing, Inc.

90 Oser Avenue, Hauppauge, N.Y. 11788
Call: 800 645-2522 or 631 273 2500
e-mail: [email protected]
www.lowel.com

255 ver. 2.0 © 2009, Lowel-Light Mfg., Inc.

120v e-studio2, 4

Model

Voltage

Continuous Power

Peak Current

Fuse Rating

e-studio2

120 VAC

0.8

1.3

3.15 A

e-studio4

120 VAC

1.7

2.5

5 A

230v e-studio2, 4

Model

Voltage

Continuous Power

Peak Current

Fuse Rating

e-studio2

230 VAC

0.4

0.6

2.5 A

e-studio4

230 VAC

0.8

1.3

3.15 A

120 - 230v e-studio 6 (when auto-setting to 120VAC or 230VAC, the below values apply)

Model

Voltage

Continuous Power

Peak Current

Fuse Rating

e-studio6

120 VAC

2.4

3.5

5 A

e-studio6

230 VAC

1.3

1.9

5 A

Lowel e-studio™ Instructions

A

Fuse

A

Accessory

Location

Output Loss/Gain e-studio6

e-studio4

e-studio2

(approx)

(Code)

(Code)

(Code)

Barndoor

Front of Fixture

N / A

FLS-620

FLS-420

FLS-220

Intensifier

Front of Fixture

+ 80%

FLS-622

FLS-422

FLS-222

Egg Crate

Front of Fixture

- 25%

FLS-624

FLS-424

FLS-224

Honeycomb Grid Black 40°

Front of Fixture

- 25%

FLS-634

FLS-434

FLS-234

Honeycomb Grid Black 30°

Front of Fixture

- 35%

FLS-633

FLS-433

FLS-233

Honeycomb Grid Black 20°

Front of Fixture

- 54%

FLS-632

FLS-432

FLS-232

Honeycomb Grid Black 40°

Front of Intensifier

- 30%

FLS-644

FLS-444

FLS-244

Honeycomb Grid Black 30°

Front of Intensifier

- 22%

FLS-643

FLS-443

FLS-243

Honeycomb Grid Black 20°

Front of Intensifier

- 46%

FLS-642

FLS-442

FLS-242

Light Control Accessories