4 = dial options – Verilink ConnecT 56K DSU (896-502110-001) Product Manual User Manual

Page 73

Advertising
background image

3 = CONFIG

ConnecT 56K DS

User Manual

3-43

Table 3-29 RDL Select Commands

Submenu 3 EIA LLB select

The EIA LLB Select option is used to specify whether or not the
ConnecT 56K DSU responds to the local loopback (LLB) input from the
DTE.

Table 3-30 EIA LLB Select Commands

Submenu 4 EIA RLB select

The EIA RLB Select option is used to specify whether or not the
ConnecT 56K DSU responds to the remote loopback (RLB) input from
the DTE.

Table 3-31 EIA RLB Select Commands

The Dial Option menu is used to store up to ten phone numbers and
define Answer operation of the ConnecT 56K DSU when it is configured
for Switched 56 operation.

Front Panel

AT
Command

Description

1=RDL IGNORED

&T5

RDL request from remote DSU
ignored

2=RDL ACCEPTED

&T4

RDL request accepted

Front Panel

AT
Command

Description

1=DISABLED

_R0

EIA LLB disabled

2=ENABLED

_R1

EIA LLB enabled

Front Panel

AT
Command

Description

1=DISABLED

_R0

EIA RLB disabled

2=ENABLED

_R1

EIA RLB enabled

4 = Dial options

4=DIAL OPTIONS

1=PHONE NUMBER

STORED NUMBER TO

2=AUTO ANSWER

1=DISABLED
2=ENABLED

EDIT: (1-10) 1

NNNNNNN

Advertising