Welltech SPCI2S Intel NetStructure SS7 Boards User Manual

Page 70

Advertising
background image

SS7 Programmer’s Manual for SPCI2, SPCI4 and CPM8 Issue 2

Page 70

Parameter Description:

bus_speed


This parameter is used to set the CT bus speed, the permissible values are as
follows:

Value

Bus speed

0 No

change

2

4.096 MHz (Reserved for future use)

3 8.192

MHz

clk_mode


This parameter determines the clocking mode for the board, the permissible
values are as follows:

Value

Clock Mode

0 No

change

1

CT bus Primary Master, driving Clock Set A

2

CT bus Secondary Master, driving Clock Set B

3

CT bus Slave, initially using Clock Set A

4

CT bus disabled

10

CT bus Primary Master, driving Clock Set B

11

CT bus Secondary Master, driving Clock Set A

12

CT bus Slave, initially using Clock Set B

When mode 4 is selected (“CT bus disabled”) the card is electrically isolated
from the other cards using the CT bus. The CT bus connection commands may
still be used, but the connections made will only be visible to this card. When
using this mode, the on-board clocks will be synchronised to the configured
pll_clk_src reference.

If the card is configured to be Slave to the CT bus then it will automatically
switch between using Clock Set A and Clock Set B if it detects a failure on the
current clock set.

When a card is acting as Primary Master it uses the clock reference set by the
pll_clk_src parameter to drive the CT bus clock.

As Secondary Master the pll_clk_src should be set to an appropriate source
ready for use if the card acting as Primary Master stops driving the CT bus
clock. Until this time, the on-board clocks on the Secondary Master card will be
synchronised to the CT bus clock provided by the Primary Master.