Westermo ODW-720-F2 User Manual

Page 18

Advertising
background image

18

6651-2235

If an optical fibre segment fails, the ODW-720 Ring Focal Point will switch mode and
start sending out data on both optical fibre ports, TX1 and TX2, simultaneously.

RX2

TX2

Device 1

Sending

Device 2

Receiving

Device 3

Reciving

Device n

Receiving

TX1

RX1

RX2

TX2

TX1

RX1

RX2

TX2

RS-232

RS-232

RS-232

Fibre

pair

Faulty

segment

Fibre

pair

Focal point

RS-232

TX1

RX1

RX2

TX2

TX1

RX1

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

ODW-720 units located to the “right” side of the failure will send data in the opposite
direction as before. Notice that still, it’s only the first ODW-720 that is able to commu-
nicate in full duplex with other units, and that other units are incable of communicating
with each other.

RX2

TX2

Device 1

Receiving

Device 2

Not sending or

receiving any data

Device 3

Sending

Device n

Not sending or

receiving any data

TX1

RX1

RX2

TX2

TX1

RX1

RX2

TX2

RS-232

RS-232

RS-232

Fibre

pair

Faulty

segment

Fibre

pair

Focal point

RS-232

TX1

RX1

RX2

TX2

TX1

RX1

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

PWR

FP

TD

RD

Advertising